What Is Passive Fire Protection? Fire Stopping Explained
Every time a pipe, cable or duct passes through a fire-rated wall or floor, it leaves a hole. If that hole isn't sealed properly, fire and smoke can move straight through it. Fire stopping is the work that closes those gaps.
It's one of the least visible parts of a building and one of the most important. Since the Building Safety Act, it's also under more scrutiny than ever. This guide explains what passive fire protection is, where fire stopping is needed, who is responsible and what tends to go wrong.
In short: Passive fire protection is built into the building. It holds fire and smoke in one area for a set time, so people can get out and firefighters can work. Fire stopping is the part that seals gaps and holes in fire-rated walls and floors, such as where pipes, cables and ducts pass through.
Passive vs active fire protection
Active fire protection does something when a fire starts. Sprinklers spray, alarms sound and smoke vents open.
Passive fire protection doesn't move. It's part of the structure, and it works all the time.
|
Passive fire protection |
Active fire protection |
|---|---|
|
Fire-rated walls and floors |
Sprinkler systems |
|
Fire doors |
Fire alarms and detectors |
|
Fire stopping around pipes, cables and ducts |
Smoke extract fans and vents |
|
Cavity barriers |
Fire suppression systems |
|
Fire-rated protection to ducts and steel |
Fire extinguishers |
A building needs both. But active systems can fail, lose water pressure or be switched off. Passive protection is there whether anyone remembers it or not. That's why gaps in it matter so much.
Compartments: the idea behind it
Most larger buildings are split into fire compartments. Each one is a box of fire-rated walls and floors designed to hold a fire back for a set time, often 30, 60 or 120 minutes.
The compartment only works if it's complete. A 60-minute wall with an unsealed hole for a pipe isn't a 60-minute wall any more.
What fire stopping is and where it's needed
Fire stopping seals gaps in compartment walls and floors with products tested to hold back fire and smoke for the same time as the wall or floor. These are the places it's needed most.
Service penetrations
Anywhere pipes, cables, cable trays or ducts pass through a fire-rated wall or floor. Different services need different products:
- Plastic pipes soften and melt in a fire, leaving an open hole. They usually need fire collars or wraps that swell with heat and crush the pipe shut.
- Metal pipes carry heat through the wall. They need sealing and sometimes insulation for a set distance either side.
- Cables and cable trays are often sealed with fire-rated batts, compounds or sealants.
See our penetration sealing service.
Linear gaps
The joints between walls and floors, walls and ceilings, and along the heads of partitions. Buildings move, so these gaps often need a seal that can flex without breaking. See linear gap sealing.
Ductwork
Ducts can carry fire and smoke from one compartment to the next. Where a duct crosses a compartment line, it needs a fire damper or fire-rated protection. Fire-rated duct insulation is one way to protect the duct itself. See fire-rated duct insulation.
Who is responsible and what paperwork to expect
In most non-domestic buildings, the "responsible person" under the Regulatory Reform (Fire Safety) Order 2005 must make sure fire safety measures are kept in good order. That includes compartmentation. In practice, this is usually the owner, the employer or the managing agent.
On new build and refurbishment projects, the principal contractor and the trades doing the work are responsible for installing fire stopping correctly. In higher-risk residential buildings, the Building Safety Act 2022 adds stricter duties and a "golden thread" of building information that has to be kept for the life of the building.
Whatever the building, fire stopping work should come with paperwork. Ask for:
- The products used, and test evidence showing they suit that wall, floor and service
- Photos of each seal before it's covered up, ideally with a unique reference number
- A plan or schedule showing where each seal is
- Labels on or next to each seal where practical
- Confirmation that the installers are trained on the products they used
If it can't be shown, don't assume it was done properly. Fire stopping behind ceilings is very hard to check once they go back up.
Need to know what's behind your ceilings and in your risers? Book a fire stopping survey.
Common faults found on surveys
- Holes left open. Old services taken out and the hole never sealed.
- New services through old seals. A new cable pushed through a sealed opening, breaking the seal.
- Expanding foam. General-purpose foam isn't fire rated. Even fire-rated foam only works in situations it has been tested for.
- The wrong product. A sealant used where a plastic pipe needed a collar.
- Mixed products. Different makers' products used in one seal without test evidence for the mix.
- Incomplete seals. Gaps left at the edges, or seals that aren't deep enough.
- No labels or records. Nobody can tell what was used, where or when.
Most of these come from later work, when another trade runs a new service and doesn't reinstate the seal. A simple permit system for any work that breaks into fire-rated walls and floors prevents a lot of them.
How to choose a fire stopping contractor
- Ask about third-party certification. Schemes such as FIRAS and IFC Certification check that installers work to tested details. Ask which scheme the contractor belongs to, then check it.
- Ask for test evidence. Every seal should match a tested detail for that wall, floor and service.
- Ask what records you'll get. Photos, references and a schedule should be standard.
- Ask who does the work. Make sure the people on site are trained on the products they're using.
- Get a survey first. On existing buildings, you can't price fire stopping properly until you know what's there.
Book a fire stopping survey
A fire stopping survey checks the penetrations, gaps and ducts in your fire-rated walls and floors. You get a record of each defect with photos, and a clear list of what to fix first. We work with facilities managers, managing agents and principal contractors across London and the South East.
To book a fire stopping survey, call 02033764802, email enquiries@icethermal.co.uk or get a quote today.
Related reading: passive fire protection, penetration sealing and linear gap sealing.
Every time a pipe, cable or duct passes through a fire-rated wall or floor, it leaves a hole. If that hole isn't sealed properly, fire and smoke can move straight through it. Fire stopping is the work that closes those gaps.
It's one of the least visible parts of a building and one of the most important. Since the Building Safety Act, it's also under more scrutiny than ever. This guide explains what passive fire protection is, where fire stopping is needed, who is responsible and what tends to go wrong.
In short: Passive fire protection is built into the building. It holds fire and smoke in one area for a set time, so people can get out and firefighters can work. Fire stopping is the part that seals gaps and holes in fire-rated walls and floors, such as where pipes, cables and ducts pass through.
Passive vs active fire protection
Active fire protection does something when a fire starts. Sprinklers spray, alarms sound and smoke vents open.
Passive fire protection doesn't move. It's part of the structure, and it works all the time.
|
Passive fire protection |
Active fire protection |
|---|---|
|
Fire-rated walls and floors |
Sprinkler systems |
|
Fire doors |
Fire alarms and detectors |
|
Fire stopping around pipes, cables and ducts |
Smoke extract fans and vents |
|
Cavity barriers |
Fire suppression systems |
|
Fire-rated protection to ducts and steel |
Fire extinguishers |
A building needs both. But active systems can fail, lose water pressure or be switched off. Passive protection is there whether anyone remembers it or not. That's why gaps in it matter so much.
Compartments: the idea behind it
Most larger buildings are split into fire compartments. Each one is a box of fire-rated walls and floors designed to hold a fire back for a set time, often 30, 60 or 120 minutes.
The compartment only works if it's complete. A 60-minute wall with an unsealed hole for a pipe isn't a 60-minute wall any more.
What fire stopping is and where it's needed
Fire stopping seals gaps in compartment walls and floors with products tested to hold back fire and smoke for the same time as the wall or floor. These are the places it's needed most.
Service penetrations
Anywhere pipes, cables, cable trays or ducts pass through a fire-rated wall or floor. Different services need different products:
- Plastic pipes soften and melt in a fire, leaving an open hole. They usually need fire collars or wraps that swell with heat and crush the pipe shut.
- Metal pipes carry heat through the wall. They need sealing and sometimes insulation for a set distance either side.
- Cables and cable trays are often sealed with fire-rated batts, compounds or sealants.
See our penetration sealing service.
Linear gaps
The joints between walls and floors, walls and ceilings, and along the heads of partitions. Buildings move, so these gaps often need a seal that can flex without breaking. See linear gap sealing.
Ductwork
Ducts can carry fire and smoke from one compartment to the next. Where a duct crosses a compartment line, it needs a fire damper or fire-rated protection. Fire-rated duct insulation is one way to protect the duct itself. See fire-rated duct insulation.
Who is responsible and what paperwork to expect
In most non-domestic buildings, the "responsible person" under the Regulatory Reform (Fire Safety) Order 2005 must make sure fire safety measures are kept in good order. That includes compartmentation. In practice, this is usually the owner, the employer or the managing agent.
On new build and refurbishment projects, the principal contractor and the trades doing the work are responsible for installing fire stopping correctly. In higher-risk residential buildings, the Building Safety Act 2022 adds stricter duties and a "golden thread" of building information that has to be kept for the life of the building.
Whatever the building, fire stopping work should come with paperwork. Ask for:
- The products used, and test evidence showing they suit that wall, floor and service
- Photos of each seal before it's covered up, ideally with a unique reference number
- A plan or schedule showing where each seal is
- Labels on or next to each seal where practical
- Confirmation that the installers are trained on the products they used
If it can't be shown, don't assume it was done properly. Fire stopping behind ceilings is very hard to check once they go back up.
Need to know what's behind your ceilings and in your risers? Book a fire stopping survey.
Common faults found on surveys
- Holes left open. Old services taken out and the hole never sealed.
- New services through old seals. A new cable pushed through a sealed opening, breaking the seal.
- Expanding foam. General-purpose foam isn't fire rated. Even fire-rated foam only works in situations it has been tested for.
- The wrong product. A sealant used where a plastic pipe needed a collar.
- Mixed products. Different makers' products used in one seal without test evidence for the mix.
- Incomplete seals. Gaps left at the edges, or seals that aren't deep enough.
- No labels or records. Nobody can tell what was used, where or when.
Most of these come from later work, when another trade runs a new service and doesn't reinstate the seal. A simple permit system for any work that breaks into fire-rated walls and floors prevents a lot of them.
How to choose a fire stopping contractor
- Ask about third-party certification. Schemes such as FIRAS and IFC Certification check that installers work to tested details. Ask which scheme the contractor belongs to, then check it.
- Ask for test evidence. Every seal should match a tested detail for that wall, floor and service.
- Ask what records you'll get. Photos, references and a schedule should be standard.
- Ask who does the work. Make sure the people on site are trained on the products they're using.
- Get a survey first. On existing buildings, you can't price fire stopping properly until you know what's there.
Book a fire stopping survey
A fire stopping survey checks the penetrations, gaps and ducts in your fire-rated walls and floors. You get a record of each defect with photos, and a clear list of what to fix first. We work with facilities managers, managing agents and principal contractors across the UK.
To book a fire stopping survey, call 02033764802, email enquiries@icethermal.co.uk or get a quote today.
Related reading: passive fire protection, penetration sealing and linear gap sealing.
You’re in good company. We’ve worked with the following commercial clients… View all
Why choose us?
- Cater to domestic, commercial and industrial facilities
- Nationwide coverage, available 24/7
- Free site survey provided prior to quotation
- Rapid response available
- A bespoke service designed to suit all your needs
- All operatives hold professional health and safety qualifications
We’re fully accredited
We take health and safety, our professional expertise and legal obligations very seriously. You can view a list of our accreditations below, or visit our Health & Safety page for more information.